CMWH Watt-hour, lack-hour meter
Features:
High accuracy 0.2%Rd/PF+0.02%FS
Output/Display Range Programmable Correspondence
The output adopts 16-bit digital/analog (D/A) conversion
Analog and digital simultaneous output, digital output (Modbus-RTU)
Provide running indicator flashing, independent display of buying and selling electricity
WH or VarH power failure memory for 10 years without additional batteries
Double row display (can be customized)
CMA Single Phase AC Ammeter
Features:
High accuracy 0.15%FS+1Counts
Programmable correspondence of output/display/setting range
The output adopts 16-bit digital/analog (D/A) conversion
Analog and digital simultaneous output, digital output (Modbus-RTU)
Value, minimum value and other functions (optional)
High isolation capability Power/input/output/enclosure
CMV Single Phase AC Voltmeter
Features:
High accuracy 0.15%FS+1Counts
Programmable correspondence of output/display/setting range
The output adopts 16-bit digital/analog (D/A) conversion
Analog and digital simultaneous output, digital output (Modbus-RTU)
Value, minimum value and other functions (optional)
High isolation capability Power/input/output/enclosure
Three-phase AC ammeter
Features:
High accuracy 0.15%FS+1Counts
Programmable correspondence of output/display/setting range
The output adopts 16-bit digital/analog (D/A) conversion
Analog and digital simultaneous output, digital output (Modbus-RTU)
Value, minimum value and other functions (optional)
High isolation capability Power/input/output/enclosure
Three-phase AC Voltmeter
Features:
High accuracy 0.15%FS+1Counts
Programmable correspondence of output/display/setting range
The output adopts 16-bit digital/analog (D/A) conversion
Analog and digital simultaneous output, digital output (Modbus-RTU)
Value, minimum value and other functions (optional)
High isolation capability Power/input/output/enclosure
CMPF Power Factor Table
Features:
High accuracy 0.02%FS+1Counts
Programmable correspondence of output/display/setting range
The output adopts 16-bit digital/analog (D/A) conversion
Analog and digital simultaneous output, digital output (Modbus-RTU)
Value, minimum value and other functions (optional)
High isolation capability Power/input/output/enclosure
CMVA AC voltage and current synthesis table
Features:
High accuracy 0.15%FS+1Counts
Programmable correspondence of output/display/setting range
The output adopts 16-bit digital/analog (D/A) conversion
Analog and digital simultaneous output, digital output (Modbus-RTU)
Value, minimum value and other functions (optional)
High isolation capability Power/input/output/enclosure
CMHZ frequency table
Features:
High accuracy 0.02%FS+1Counts
Programmable correspondence of output/display/setting range
The output adopts 16-bit digital/analog (D/A) conversion
Analog and digital simultaneous output, digital output (Modbus-RTU)
Value, minimum value and other functions (optional)
High isolation capability Power/input/output/enclosure
CMTR Platinum Resistance Thermometer
Features:
High accuracy 0.15%RS+0.3 degrees
Programmable correspondence of output/display/setting range
The output adopts 16-bit digital/analog (D/A) conversion
Simultaneous pulse and digital output, digital output (Modbus-RTU)
Value, minimum value, and other functions (optional)
High isolation capability Power/input/output/enclosure
CMTC Thermocouple Thermometer
Features:
High accuracy 0.2%FS+0.3 degrees Celsius
Output/display/setting range Programmable correspondence
The output adopts 16-bit digital/analog (D/A) conversion
Analog and digital simultaneous output, digital output (Modbus-RTU)
Value, minimum value and other functions (optional)
High isolation capability Power/input/output/enclosure
CMS Two-Wire DC Ratio Meter
Features:
High accuracy 0.04%FS+2 Counts
Output/display/setting range Programmable correspondence
The output adopts 16-bit digital/analog (D/A) conversion
Analog and digital simultaneous output, digital output (Modbus-RTU)
Value, minimum value and other functions (optional)
High isolation capability Power/input/output/enclosure
CME DC Ratio Table
Features:
High accuracy 0.04%FS+2 Counts
Output/display/setting range Programmable correspondence
The output adopts 16-bit digital/analog (D/A) conversion
Analog and digital simultaneous output, digital output (Modbus-RTU)
Value, minimum value and other functions (optional)
High isolation capability Power/input/output/enclosure
CMW Watt, Wattmeter
Features:
High accuracy 0.2%Rd/PF+0.02%FS
Output/Display Range Programmable Correspondence
The output adopts 16-bit digital/analog (D/A) conversion
Analog and digital simultaneous output, digital output (Modbus-RTU)
High isolation capability Power/input/output/enclosure
CMWWH Watt, Watt-hour Composite Table
Features:
High accuracy 0.2%Rd/PF+0.02%FS
Output/Display Range Programmable Correspondence
The output adopts 16-bit digital/analog (D/A) conversion
Analog and digital simultaneous output, digital output (Modbus-RTU)
Provide running indicator flashing, independent display of buying and selling electricity
WH or VarH power failure memory for 10 years without additional batteries
Double row display, can display instantaneous value and cumulative value at the same time (can be customized)
CMDW DC Wattmeter
Features:
High accuracy 0.15%RO+CountS
Output/Display Range Programmable Correspondence
16-bit output/display digital/analog (D/A) conversion
Analog and digital simultaneous output, digital output (Modbus-RTU)
High isolation capability Power/input/output/enclosure