DM1249
A thermometer for multiple SCRs (1ψ or 3ψ)
Applicable to all products of the company (P3, Z2, P1, APS, 1A, 1V, TMPT, ZT, and other products)
Can be used for signal conversion, 4 groups of different signals can be output for signal transmission and synchronization signals
Input signal: Standard: 4-20mA
Optional: 0-20mA, 1-5V, 0-5V, 0-10V, 2-10V
Dimensions (mm): 85 (L) × 43 (W) × 40 (H) (including aluminum rail seat)
AC signal [AC→DC] converter (DM1432)
Solve the transmission rate caused by system crash or interference caused by power interference or system factors in MODBUS digital transmission system.
There is no communication protocol problem, troubleshooting is easy and easy to troubleshoot system maintenance and purchase of spare parts in the future.
The signal transmission rate is faster than digital transmission, which greatly improves the system's processing signal performance.
With single group and group selection function, and the signal is completely isolated, multiple sets of outputs can be used in parallel, depending on the control signal driving capability.
It has output impedance matching correction function (0~5V or 0~10V) and has output short circuit protection.
VR1, VR2, and VR3 output correction buttons for each group.
Dimensions (LxWxH mm): 110 x 45 x 50
Ordering Information: Product Name = DM1432
A thermometer for multiple SCRs (1ψ or 3ψ) and applies to all products of the company (P3, Z2, P1, APS, 1A, 1V, TMPT, ZT, etc.)
The output of Out1, Out2, Out3, and Out4 can be individually adjusted or corrected by the corresponding VR.
Can be used for signal conversion, for signal transmission purposes and synchronous signal monitoring
Synchronous input signal: Standard: 4-20mA (optional: 0-20mA, 1-5V, 0-5V, 0-10V)
Standard output: 4 groups 4-20mA
Power supply: 18Vac or 24Vdc
Dimensions (mm): 85mm (L) x 32mm (W) x 55mm (H) (including aluminum rail seat)
Ordering Information: Product Name = DM1030B - A B
A thermometer for multiple SCRs (1ψ or 3ψ)
Applicable to all products of the company (P3, Z2, P1, APS, 1A, 1V, TMPT, ZT, and other products)
Can be used for signal conversion, 4 groups of different signals can be output for signal transmission and synchronization signals
Input signal: Standard: 4-20mA
Optional: 0-20mA, 1-5V, 0-5V, 0-10V, 2-10V
Dimensions (mm): 85 (L) × 43 (W) × 40 (H) (including aluminum rail seat)
Ordering Information: Product Name = DM1501
Suitable for any DC pulse (P.W.M) output control application.
This product standard is 24Vdc/3A or less.
Duty Frequency is adjustable, frequency range (10Hz~1KHz) or fixed (fixed Frequency).
Special specifications voltage / current are available to customers.
Ordering Information: Product Name = DM1024 - A B
Can be applied to any DC pulse modulation (P.W.M) control occasion.
The maximum current of this type of product: 3A.
Applicable to any magnetic powder brake below 24V/3A.
Special specifications of voltage / current can be customized according to customer needs.
Ordering Information: Product Name = DM1405 - A
Check if the belt is slack and slow down.
Check for malfunction, reduce speed, and break the chain.
Proximity switch (NPN)
Speed setting range: 1 160R.P.M~5000R.P.M (2.5%) (standard)
2 6R.P.M~600R.P.M (97.5%)
Power supply voltage: 24Vdc
Start detection: Closed
Start detection delay: 0 to 3 seconds Adjustable (VR1)
Fault light display and Relay output: (220Vac / 0.1A)
Reset: Normal detection (open circuit) Reset (closed circuit)
Work cycle or sensor detection area ratio: (%) (duty cycle): 2% to 98%
Working period
(T1/T2×100%)→T1: induction time, T2: cycle of one revolution of the motor, T3: detection time (VR2)
Cancel the alarm method: a Close (b) b Stop the start c Stop the power supply
Ordering Information: Product Name = DM0750